Revision 3 posted to Road and Site Design - Wiki by Jacquelyn Pettus on 3/19/2015 5:28:54 PM

Product(s):InRoads
Version(s):08.11.07.615
Area: Geometry
Original Author:Sanders Thomas, Bentley Technical Support Group

 

Problem:

I am trying to load InRoads ALG file in ProjectWise and receiving a message "Unable to lock file". The file does not open. I can export the file and open locally, but it does not work when I import the file back to ProjectWise.

 

Solution:

Go to Tools < Application Add-ins. Check to make sure you have "Variable Manager" toggled on.

Go to Tools > Variable Manager> Command Behavior, ensure that"Geometry- Alternate Workflow with ProjectWise" is selected. This command will automatically check-out and check-in the ALG and should resolve this issue.

 

Tags: ProjectWise Intergration, Alignments, Export